Ensuring Long-Term Data Continuity for Planet’s Surface Reflectance Products

Overview

At Planet, we are committed to providing our customers with high-quality, scientifically robust data that is reliable for long-term analysis. To ensure the continuity and quality of our Surface Reflectance (SR) products, we are transitioning the underlying atmospheric correction input from the retiring MODIS (Moderate Resolution Imaging Spectroradiometer) sensor to the more modern VIIRS (Visible Infrared Imaging Radiometer Suite) sensor on November 30, 2026. The originally scheduled date for retiring MODIS was expedited from February 2027 to December 1, 2026, so Planet has moved quickly to implement this transition effectively. 

This document provides a comprehensive overview of this change, its technical rationale, and the potential impacts on your data and workflows.

Why the Transition is Happening

The MODIS sensors on board the Terra and Aqua satellites have been instrumental in Earth observation for over two decades. However, the MODIS mission is in its final operational phase and will cease collecting data on December 1, 2026 (Terra) and mid 2027 (Aqua). This planned end-of-life for the MODIS program necessitates a solution to ensure uninterrupted service for our customers.

VIIRS is the NASA-designated successor to MODIS, and a key component of the Joint Polar Satellite System (JPSS). By transitioning to VIIRS data, we are:

  • Ensuring Long-Term Stability: Moving to a modern, actively maintained data source supports persistent availability of the necessary inputs for our atmospheric correction processes.
  • Maintaining Product Quality: The VIIRS sensor is designed with improved radiometric performance and a wider swath, which enhances our ability to correct for atmospheric effects.
  • Providing Continuity: The VIIRS mission was specifically designed to continue the long-term data record of MODIS, ensuring a high degree of compatibility between the two data sets.

What This Means for the SR Product

  1. Date of Transition: The SR product generation pipeline will be officially switched to use VIIRS data on Monday, November 30, 2026. All new SR products generated after this date will be based on the new inputs.
  2. Metadata Transparency: To ensure transparency, every SR product generated using the new pipeline will contain a specific metadata tag in the GeoTIFF header. This tag will explicitly state that the product was atmospherically corrected using VIIRS data.
  3. Data Consistency: We have taken care to minimize disruptions to data consistency. Our SR algorithm, which uses a look-up table (LUT) approach based on the 6SV2.1 radiative transfer code, has been updated to use VIIRS-derived atmospheric parameters. While the absolute values may be slightly different, the relative spectral relationships and overall quality is expected to be consistent. However, the temporal offset between afternoon VIIRS acquisitions and morning PlanetScope® imagery can introduce discrepancies in atmospheric correction and resulting SR values in limited cases. This may manifest as an overcorrection that artificially lowers reflectance values, visually resulting in darker imagery or slight color shifts. 
  4. No Impact on Latency: We do not anticipate any changes to our current SR product delivery latency.

How to Identify the Data Source for Your SR Product

The data source used to generate your Surface Reflectance product  can be found in the GeoTIFF metadata header. All newly generated products will contain a specific metadata field that explicitly states the source.

  • For products generated on or after November 30, 2026: The metadata will indicate that the product was generated using VIIRS data.
"aot_source": "viirs" or "viirs_nrt"
"water_vapor_source": "viirs" or "viirs_nrt"
"ozone_source": "viirs" or "viirs_nrt"
  • For products generated before November 30, 2026: The metadata will indicate that the product was generated using MODIS data.
    • MODIS Terra
"aot_source": "mod09cma" or "mod09cma_nrt"
"water_vapor_source": "mod09cma" or "mod09cma_nrt"
"ozone_source": "mod09cma" or "mod09cma_nrt"
  • MODIS Aqua
"aot_source": "myd09cma" or "myd09cma_nrt"
"water_vapor_source": "myd09cma" or "myd09cma_nrt"
"ozone_source": "myd09cma" or "myd09cma_nrt"

Which Planet Satellites Does This Apply To?

This transition applies to the SR products generated from the following Planet satellite constellations:

  • PlanetScope
  • SkySat®
  • Pelican™

This change affects the atmospheric correction process for all of these product lines, ensuring a consistent data source for all of our customers.

 

Frequently Asked Questions (FAQ)

Will this change break my existing workflows?

For most customers, the transition should be seamless. However, if your applications are sensitive to minor shifts in absolute SR values, we recommend validating your workflows with a small set of newly generated data. The metadata tag can be used to identify new products.

Will Planet reprocess old data using VIIRS?

Planet does not plan to reprocess historical SR products using VIIRS. All products generated before November 30, 2026, will remain in their original form.

Which item-type and asset-type will this apply?

Item-types: PSScene, SkySatScene, SkySatCollect, PelicanScene

Asset-types: 

  • PSScene: ortho_analytic_4b_sr, ortho_analytic_8b_sr
  • SkySatCollect/SkySatScene: ortho_analytic_sr
  • PelicanScene: ortho_analytic_sr

How do I identify which sensor was used for atmospheric correction?

The GeoTIFF header of each SR product will contain a metadata string that specifies the source of the atmospheric data.

  • VIIRS
"aot_source": "viirs" or “viirs_nrt"
"water_vapor_source": "viirs" or “viirs_nrt"
"ozone_source": “viirs" or "viirs_nrt"
  • MODIS Terra
"aot_source": "mod09cma” or "mod09cma_nrt"
"water_vapor_source": "mod09cma" or "mod09cma_nrt"
"ozone_source": “mod09cma" or "mod09cma_nrt"
  • MODIS Aqua
"aot_source": "myd09cma” or "myd09cma_nrt"
"water_vapor_source": "myd09cma" or "myd09cma_nrt"
"ozone_source": "myd09cma" or "myd09cma_nrt"

 

Is there a fallback for VIIRS in case VIIRS sensors have issues? 

Until the end of life of MODIS Aqua, MODIS Aqua will be the fallback while Planet assesses what additional fallback to VIIRS can be incorporated to the pipeline in case of emergencies. 

What is the impact on latency?

We do not anticipate any changes to our current SR product delivery latency. 

When requesting the archive (processed using MODIS) as well as new images (using VIIRS), will there be noticeable differences in SR values given that some part of the archive was processed using MODIS data vs VIIRS?

We have run a global land mass comparison of VIIRS generated SR to production MODIS generated SR data and have found minimal differences between the surface reflectance values. The following table and charts show the gain, offset, % uncertainty, and r2.

MODIS versus VIIRS 

Band Gain Offset % Uncertainty R2

coastal_blue

0.9357

0.008

5.378

0.9906

blue

0.9486

0.0068

5.434

0.9933

green_i

0.9657

0.0045

4.328

0.9937

green

0.9564

0.0053

5.482

0.9942

yellow

0.9584

0.0049

5.231

0.9940

red

0.9582

0.0045

3.996

0.9950

red edge

0.9542

0.0041

2.863

0.9939

nir

0.9697

0.0035

0.3370

0.9940

 

What if I have additional questions?

Our support team is fully briefed on this change and is available to assist you with any questions. Please contact us at https://support.planet.com/hc/en-us/requests/new .

Was this article helpful?
0 out of 0 found this helpful

Comments